the measurement took place in a relatively short time 
interval. 

 
These conditions ensured a minimal effect on the measurement. The 
constant conditions did not affect the results of measuring. 
According to the results in the previous section, it is possible to 
compare the individual minimum widths of the tolerance field for 
each measuring head. 
 
One-side tolerance. The results for the fixed head VAST GOLD 
show an upper tolerance limit of 39.9979 mm and a lower tolerance 
limit of 39.9865 mm. This means that the width of the tolerance 
field is 0.0114 mm. For the VAST XXT rotating head, the upper 
tolerance limit is 39.9979 mm and the lower tolerance limit is 
39.9941 mm. This means that the width of the tolerance field is 
0.0038 mm. 
 
Similar results are obtained for the bilateral width of the tolerance 
field. The results for the VAST GOLD fixed head show an upper 
tolerance limit of 40.001 mm and a lower tolerance limit of 39.991 
mm. This means that the width of the tolerance field is 0.014 mm. 
For the VAST XXT rotating head, the upper tolerance limit is 
40.001 mm and the lower tolerance limit is 39.996 mm. This means 
that the width of the tolerance field is 0.005 mm. 
 
Based on these results, it can be said that the VAST XXT rotary 
head has a tolerance field width 3 times smaller than the fixed 
VAST GOLD head. 

Sources 
 
1.

 

KRENAUER, J. Porovnání 

vyhodnocování vhodnosti měřícího. 

Bachelor thetis, UWB Pilsen 2017.  

2.

 

KUBÁTOVÁ, D. 

Nejistoty měření, studijní materiály 

(Measurement uncertainties, study materials). UWB Pilsen 
2020 

3.

 

TŘEŠTÍK, J. Vyšetřování způsobilosti měřidla "Metoda SPC – 
Ford" (Examination of the suitability of the meter "SPC method 
- Ford").
 2020. Cited by: http://www.trestik.cz/msa-spc-ford 

4.

 

MM Spektrum. 

Zkušenosti se stanovením způsobilosti měřidel 

ve Škoda Auto. MM Spektrum 2004 / 6, 16.06.2004 rubrika 
Trendy / Jakost, Strana 42 

5.

 

Web ZEISS. 

Prismo navigator. 2020. Cited by: 

https://www.zeiss.cz/metrologie/produkty/systemy/bridge-type-
cmms/prismo.html 

6.

 

Web ZEISS. Fixed head Vast gold. 2020. Cited by: 
https://www.zeiss.com.au/metrology/products/sensors/on-
cmm/tactile-scanning-probe/vast-gold.html 

7.

 

Web ZEISS. Rotating head Vast XXT. 2020. Cited by: 
https://www.zeiss.com.au/metrology/products/sensors/on-
cmm/tactile-scanning-probe/vast-xxt.html 

8.

 

JIROUŠEK, P. 

Způsobilost systému měření ve výrobě 

převodovek ŠKODA AUTO a.s. Diploma thetis, Mladá Boleslav 
2012 

 

 

Vol. 9, Issue 1

99